Variis exemplaribus praesto pro diversis postulationem
Aliquam available pro speciali postulationem
Exemplar | Focus Longitudo | F# | Spectrum | FPA | FOV |
LWT25/75 | 25~75mm | 1.2 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm 1280× 1024, 12µm | 3.5°×2.6°~15°×11° 8.3°×6.6°~24°×19° 5.9°×4.7°~17.5°× 14° 11.7°×9.4°~ 17.5°× 14° |
LWT15/180 | 15~180mm | 1.3 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm | 2.1°×1.6°~17.5°×13° 3.5°×2.8°~39.8°×32.3° 2.4°×2°~29°×23.5° |
LWT20/100 | 20~100mm | 1.2 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm 1280× 1024, 12µm | 2.6°× 1.87°~13°×9.8° 6.2°×5°~30.5°× 24.5° 4.4°×3.5°~21.7°× 17.5° 8.8°×7°~42°×34° |
LWT20/120 | 20~120mm | 1.2 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm | 2.2°× 1.6°~13°×9.8° 5.2°×4.1°~30.5°× 24.5° 3.7°×2.9°~21.7°× 17.5° |
LWT25/150 | 25~150mm | 1.2 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm | 1.75°× 1.3°~10.5°×7.9° 4.2°×3.3°~24.5°× 19.7° 2.9°×2.4°~ 17.5°× 14° |
LWT25/150L | 25~150mm | 1.4 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm | 1.75°× 1.3°~10.5°×7.9° 4.2°×3.3°~24.5°× 19.7° 2.9°×2.4°~ 17.5°× 14° |
LWT30/150H | 30~150mm | 1.0 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm | 1.75°× 1.3°~8.8°×6.6° 4.2°×3.3°~20.6°× 16.1° 2.9°×2.4°~14.6°× 11.7° |
LWT30/150 | 30~150mm | 1.2 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm 1280× 1024, 12µm | 1.8°× 1.3°~8.8°×6.6° 4.2°×3.3°~20.6°× 16.1° 2.9°×2.4°~14.6°× 11.7° 5.9°×4.7°~28.7°×23.1° |
LWT30/180 | 30~180mm | 1.4 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm | 1.5°×1.1°~8.8°×6.6° 3.5°×2.8°~20.6°× 16.1° 2.4°×2°~14.6°× 11.7° |
LWT25/225 | 25~225mm | 1.2~1.5 | 8~12µm | 384×288, 12µm 640×512, 17µm 640×512, 12µm 1280× 1024, 12µm | 1.17°×0.88°~10.5°×7.9° 2.8°×2.2°~24.5°× 19.7° 1.9°×1.5°~17.5°× 14° 3.9°×3.1°~42°×34.1° |
Scelerisque lens denudatus late usus est in cameris thermis, thermographia observationis, industriae, medicinae.Sunt maxime 2 generis lentium pro zoom lens.
Continuum zoom lens principale ponitur pro camera PTZ, et ratio RCWS.Lata FOV ad quaerendum, Angusta FOV ad quaerendum et tendendum.Usor potest zoom in aliquo FOV ad scopum reprimere.
Dual FOV lens principaliter adhibetur ad applicationem defensionis.Tantum 2 FOV fac illud velocissimum inter Latam FOV et Angustum FOV flectendum.
Focus autocineticus praesto est e core, aut triginta parte umbilici autocineti tabula.Auto focus velocius tempus minus quam 2 secundis praebemus.
Aliquam sit amet elit.Ut LABIUM acuta/dimensio, protocollum, cochleae foramen...
Connector ad nucleum scelerisque est partes vexillum si requiratur.Nos omnes huiusmodi iungo secundum exigentiam praebere possumus.